SKU - SD72
Meivertor Single-Use Disposable Tips (100 pairs)
Meivertor Single-Use Disposable Tips are made from medical-grade silicone and designed for safe, hygienic eyelid eversion in clinical settings.
SKU - SD73
Meibomian Gland Expressor Forceps for mild or aggressive expression of the Meibomian gland.
iExpressor meibomian gland expression forcep VMF100
Targeted Expression from the Gland Base
The iExpressor Forceps are engineered with a specialized tapered design that enables clinicians to access the base of the meibomian glands for more effective expression. The elongated, wider paddles provide secure contact with the eyelid, minimizing slippage and reducing patient discomfort during the procedure. By reaching deeper and expressing multiple glands at once, the iExpressor ensures a more thorough release of meibum, supporting improved tear film stability and greater dry eye symptom relief.
Enhance Outcomes with Pre-Treatment Warm Compress
For best clinical outcomes, we recommend pairing the iExpressor Forceps with our iFlo USB heating eye masks. Applying a warm compress prior to the procedure helps to soften and liquefy the meibum, making subsequent meibomian gland expression smoother, more efficient, and more comfortable for the patient. This simple preparatory step not only enhances treatment effectiveness but also improves overall patient experience during expression surgery.
Clinical Demonstration of iExpressor Forceps
Dr. Bruce Dornn demonstrates the iExpressor Meibomian Gland Expression Forceps, highlighting its vertical insertion technique and larger paddles that enable multi-gland expression for faster, more effective dry eye treatment.
Video link: https://youtu.be/xRr0mtlFrFQ
|
Specification |
VMF-9402 |
|
Material |
Premium Stainless Steel |
|
Length |
120mm |
|
Tip size |
6X12 (mm) |
|
Package Dimension |
140mm x 40mm x 25mm (L/W/H) |
|
Weight |
20g |
| SKU | SD73 |
| Brand | VisuScience |
| Category | Equipment, Instruments & Equipment |
| Unit Of Measure | 1 |
For use by trained eye care professionals only.
1. Heat the patient's eyelids using a warm compress or therapeutic device for the recommended time prior to expression.
2. Apply a topical anesthetic drop if appropriate.
3. Position the patient at the slit lamp.
4. Place the paddles of the forceps inside the eyelid (between the eye and the inner eyelid), parallel to the meibomian glands.
5. Apply gentle, controlled pressure to compress and squeeze out the oil from the meibomian glands.
6. Move along each gland from the medial to lateral canthus.
7. Repeat for upper and lower eyelids of each eye.
Care: All instruments should be cleaned and sterilised between patients using standard sterilisation methods (autoclaving suitable).
Warnings:
- For professional use only.
- Single hand, easy-grip handle, German Stainless Steel.
- Apply gentle pressure only to avoid patient discomfort.
Material: German Stainless Steel forceps. Single-handed easy-grip handle design. Oval-shaped closed paddles (10mm diameter, 1mm thick), angled at 14 degrees. Autoclavable for sterilisation between patients. No chemical ingredients
- this is a physical surgical/clinical tool.